久热精品人妻视频,人人妻人人妻人人av,亚洲无码天堂在线观看,澳门成AV人片在线观看无码,久久国产精品二区,亚洲无码免费观看视频

產(chǎn)品詳情
  • 產(chǎn)品名稱(chēng):SlitHomolog2(Drosophila)(SLIT2) ELISA Kit

  • 產(chǎn)品型號(hào):
  • 產(chǎn)品廠(chǎng)商:國(guó)內(nèi)供應(yīng)3
  • 產(chǎn)品文檔:
你添加了1件商品 查看購(gòu)物車(chē)
簡(jiǎn)單介紹:
SlitHomolog2(Drosophila)(SLIT2) ELISA Kit
詳情介紹:
Purpose This immunoassay kit allows for the in vitro quantitative determination of human Slit2 concentrations in cell culture supernates, serum, plasma and other biological fluids.
Sample Type Cell Culture Supernatant, Serum, Plasma, Biological Fluids
Analytical Method Quantitative
Detection Method Colorimetric
Specificity This assay recognizes recombinant and natural human Slit2.
Cross-Reactivity (Details) No significant cross-reactivity or interference was observed.
Characteristics Homo sapiens,Human,Slit homolog 2 protein,Slit-2,SLIT2,SLIL3
Components Reagent (Quantity):
  • Assay plate (1),
  • Standard (2),
  • Sample Diluent (1×20 mL),
  • Assay Diluent A (1×10 mL),
  • Assay Diluent B (1×10 mL),
  • Detection Reagent A (1×120 μL),
  • Detection Reagent B (1×120 μL),
  • Wash Buffer(25 x concentrate) (1×30 mL),
  • Substrate (1×10 mL),
  • 2 Stop Solution (1×10 mL),
  • Plate sealer for 96 wells (5),
  • Instruction (1)
Material not included Microplate reader. Pipettes and pipette tips. EP tube Deionized or distilled water.
Alternative Name SLIT2 (SLIT2 ELISA Kit Abstract)
Background Slit2 plays a vital role in axon guidance by signaling through Robo receptors. Recent evidence suggests that Slit2 protein may function in other settings because human and Xenopus Slit2 has been shown to inhibit leukocyte chemotaxis. SLIT2 protein is a putative ligand for the ROBO receptors. ROBO1 is inactivated by promoter region hypermethylation in <,20% of="" human="" cancers.="" slit2="" is="" an="" excellent="" candidate="" tumor="" suppressor="" gene="" for="" colorectal="" cancer.="" has="" activity="" and="" that="" it="" epigenetically="" silenced="" in="">,40% of lung and breast tumors. SLIT2 promoter region methylation was found in 23 (72%) of 32 primary colorectal cancers. In contrast, normal colorectal mucosa from the same patients exhibited significantly lower levels of SLIT2 promoter region hypermethylation. SLIT2 methylation was reversed and expression restored by treating colorectal tumor cell lines with the demethylating agent 5-aza-2-deoxycytidine. Loss of heterozygosity at D4S1546 marker, which maps within 100 kb of the SLIT2 gene, was observed in 39% of the methylated tumors. Furthermore, SLIT2 epigenetic silencing was independent of ROBO1/p16/RASSF1A hypermethylation. The presence of SLIT2 methylation was also independent of the presence of K-RAS mutations. Ectopic expression of SLIT2 diminished the ability to form colonies in two colorectal tumor cell lines. In addition, conditioned medium from SLIT2-transfected COS-7 cells reduced cell growth and induced apoptosis in SW48 colorectal tumor cell line.
Gene ID 3100
Pathways Regulation of Actin Filament Polymerization, Regulation of Cell Size, Smooth Muscle Cell Migration
Sample Volume 100 μL
Plate Pre-coated
Protocol The microtiter plate provided in this kit has been pre-coated with an antibody specific to Slit2. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated polyclonal antibody preparation specific for Slit2 and Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB substrate solution is added to each well. Only those wells that contain Slit2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 2 nm. The concentration of Slit2 in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Reagent Preparation

Bring all reagents to room temperature before use. Wash Buffer - If crystals have formed in the concentrate, warm to room temperature and mix gently until the crystals have completely dissolved. Dilute 30 mL of Wash Buffer Concentrate into deionized or distilled water to prepare 750 mL of Wash Buffer. Standard - Reconstitute the Standard with 1.0 mL of Sample Diluent. This reconstitution produces a stock solution. Allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making serial dilutions (Making serial dilution in the wells directly is not permitted). The undiluted standard serves as the high standard. The Sample Diluent serves as the zero standard (0 ng/ml).

Sample Collection Cell culture supernates - Remove particulates by centrifugation and assay immediately or aliquot and store samples at ≤ -20 °C. Avoid repeated freeze-thaw cycles. Serum - Use a serum separator tube (SST) and allow samples to clot for 30 minutes before centrifugation for 15 minutes at approximately 1000 x g. Remove serum and assay immediately or aliquot and store samples at -20 °C. Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 1000 x g at 2 - 8 °C within 30 minutes of collection. Store samples at ≤ -20 °C. Avoid repeated freeze-thaw cycles. Note: Citrate plasma has not been validated for use in this assay.
Assay Procedure

Allow all reagents to reach room temperature (Please do not dissolve the reagents at 37 °C directly.). All the reagents should be mixed thoroughly by gently swirling before pipetting. Avoid foaming. Keep appropriate numbers of strips for 1 experiment and remove extra strips from microtiter plate. Removed strips should be resealed and stored at 4 °C until the kits expiry date. Prepare all reagents, working standards and samples as directed in the previous sections. Please predict the concentration before assaying. If values for these are not within the range of the standard curve, users must determine the optimal sample dilutions for their particular experiments.
1. Add 100 μL of Standard, Blank, or Sample per well. Cover with the Plate sealer. Incubate for 2 hours at 37 °C .
2. Remove the liquid of each well, don ’ t wash.
3. Add 100 μL of Detection Reagent A working solution to each well. Cover with the Plate sealer. Incubate for 1 hour at 37 °C . Detection Reagent A working solution may appear cloudy. Warm to room temperature and mix gently until solution appears uniform.
4. Aspirate each well and wash, repeating the process three times for a total of three washes. Wash by filling each well with Wash Buffer (approximately 400 μL) using a squirt bottle, multi-channel pipette, manifold dispenser or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels.
5. Add 100 μL of Detection Reagent B working solution to each well. Cover with a new Plate sealer. Incubate for 1 hours at 37 °C .
6. Repeat the aspiration/wash as in step 4.
7. Add 90 μL of Substrate Solution to each well. Cover with a new Plate sealer. Incubate within 30 minutes at 37 °C . Protect from light.
8. Add 50 μL of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
9. Determine the optical density of each well at once, using a microplate reader set to 450 nm.
Important Note:
1. Absorbance is a function of the incubation time. Therefore, prior to starting the assay it is recommended that all reagents should be freshly prepared prior to use and all required strip-wells are secured in the microtiter frame. This will ensure equal elapsed time for each pipetting step, without interruption.
2. Please carefully reconstitute Standards or working Detection Reagent A and B according to the instruction, and avoid foaming and mix gently until the crystals have completely dissolved. The reconstituted Standards can be used only once. This assay requires pipetting of small volumes. To minimize imprecision caused by pipetting, ensure that pipettors are calibrated. It is recommended to suck more than 10 μ l for once pipetting.
3. To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary. Do not allow wells to sit uncovered for extended periods between incubation steps. Once reagents have been added to the well strips, DO NOT let the 5 strips DRY at any time during the assay.
4. For each step in the procedure, total dispensing time for addition of reagents to the assay plate should not exceed 10 minutes.
5. To avoid cross-contamination, change pipette tips between additions of each standard level, between sample additions, and between reagent additions. Also, use separate reservoirs for each reagent.
6. The wash procedure is critical. Insufficient washing will result in poor precision and falsely elevated absorbance readings.
7. Duplication of all standards and specimens, although not required, is recommended.
8. Substrate Solution is easily contaminated. Please protect it from light.

Calculation of Results

Average the duplicate readings for each standard, control, and sample and subtract the average zero standard optical density. Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the x-axis against the concentration on the y-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the SAA concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. It is recommended to use some related software to do this calculation, such as curve expert 13.0. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.

Restrictions For Research Use only
Handling Advice 1. The kit should not be used beyond the expiration date on the kit label.
2. Do not mix or substitute reagents with those from other lots or sources.
3. If samples generate values higher than the highest standard, further dilute the samples with the Assay Diluent and repeat the assay. Any variation in standard diluent, operator, pipetting technique, washing technique,incubation time or temperature, and kit age can cause variation in binding.
4. This assay is designed to eliminate interference by soluble receptors, ligands, binding proteins, and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
Storage 4 °C/-20 °C
Storage Comment The Assay Plate, Standard, Detection Reagent A and Detection Reagent B should be stored at -20°C upon being received. After receiving the kit , Substrate should be always stored at 4°C.
Supplier Images
ELISA image for Slit Homolog 2 (Drosophila) (SLIT2)  ELISA Kit (ABIN578927) Slit Homolog 2 (Drosophila) (SLIT2) ELISA Kit
佛坪县| 内丘县| 芜湖县| 葵青区| 丹寨县| 疏勒县| 古丈县| 天峻县| 九龙城区| 天水市| 上杭县| 南靖县| 平乐县| 平果县| 新龙县| 比如县| 富阳市| 贡山| 青阳县| 梓潼县| 三亚市| 阳朔县| 舒城县| 克拉玛依市| 沧州市| 南丰县| 农安县| 获嘉县| 渝中区| 白河县| 浦东新区| 肇庆市| 衡阳市| 惠来县| 石楼县| 南宁市| 长治市| 赫章县| 安国市| 互助| 长沙县|