AGE ELISA Kit(AdvancedGlycationEndProduct)
詳情介紹:
Purpose The kit is a competitive inhibition enzyme immunoassay technique for the in vitro quantitative measurement of AGE serum, plasma, tissue homogenates and other biological fluids.
Sample Type Biological Fluids, Plasma, Serum, Tissue Homogenate
Analytical Method Quantitative
Detection Method Colorimetric
Specificity This assay has high sensitivity and excellent specificity for detection of this index.
Cross-Reactivity (Details) No significant cross-reactivity or interference between this index and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross- reactivity detection between this index and all the analogues, therefore, cross reaction may still exist.
Sensitivity 44 ng/mL
Components
  • Pre-coated, ready to use 96-well strip plate
  • Standard (freeze dried)
  • Standard Diluent
  • Detection Reagent A
  • Detection Reagent B
  • Assay Diluent A
  • Assay Diluent B
  • TMB
  • Stop Solution
  • Wash Buffer (30X)
  • Plate sealer for 96 wells
  • Instruction manual
Material not included
  1. Microplate reader with 450 ± 10nm filter.
  2. Precision single or multi-channel pipettes and disposable tips.
  3. Eppendorf Tubes for diluting samples.
  4. Deionized or distilled water.
  5. Absorbent paper for blotting the microtiter plate.
  6. Container for Wash Solution.
Background Synonyms: AGEs, Advanced Glycation End Products
Sample Volume 100 μL
Assay Time 1 - 4.5 h
Plate Pre-coated
Protocol 1. Prepare all reagents, samples and standards
2. Add 50 μL standard or sample to each well. And then add 50 μL prepared Detection Reagent A immediately. Shake and mix. Incubate 1 hour at 37 °C
3. Aspirate and wash 3 times
4. Add 100?L prepared Detection Reagent B. Incubate 30 minutes at 37 °C
5. Aspirate and wash 5 times
6. Add 90?L Substrate Solution. Incubate 15-25 minutes at 37 °C
7. Add 50?L Stop Solution. Read at 450nm immediately.
Assay Procedure

This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to the index has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled the index and unlabeled the index (Standards or samples) with the pre-coated antibody specific to the index. After incubation the unbound conjugate is washed off. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of the index in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of the index in the sample.

Assay Precision
  • Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
  • Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
  • CV(%) = SD/meanX100
  • Intra-assay: CV<10%
  • Inter-assay: CV<12%
Restrictions For Research Use only
Precaution of Use The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
Handling Advice The stability of ELISA Kit is determined by the loss rate of activity. The loss rate of this kit is less than 5?% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Storage 4 °C,-20 °C
Storage Comment The Assay Plate, Standard, Detection Reagent A and Detection Reagent B should be stored at -20°C upon being received. After receiving the kit , Substrate should be always stored at 4°C.Other reagents are kept according to the labels on vials. But for long term storage, please keep the whole kit at -20°C. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. The test kit may be used throughout the expiration date of the kit (six months from the date of manufacture). Opened test kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
Expiry Date 12 months
汶上县| 湟中县| 扶绥县| 岗巴县| 灵璧县| 丹棱县| 洪雅县| 高平市| 句容市| 屯昌县| 赤水市| 盐亭县| 三门峡市| 南京市| 应用必备| 漠河县| 辽阳县| 鄂州市| 澄江县| 阳高县| 海丰县| 阳新县| 吉水县| 长宁县| 休宁县| 东兰县| 景德镇市| 宁阳县| 嘉善县| 海原县| 永新县| 海伦市| 牙克石市| 长沙县| 新乡市| 微博| 上思县| 石嘴山市| 凤阳县| 清涧县| 万州区|