  • 產(chǎn)品名稱:HumanSerumAbundantProteinArrayQ1

  • 產(chǎn)品型號:
  • 產(chǎn)品廠商:RayBiotech
  • 產(chǎn)品文檔:
你添加了1件商品 查看購物車
簡單介紹:
HumanSerumAbundantProteinArrayQ1
詳情介紹:
Purpose Quantibody? Human Serum Abundant Protein Array 1 Kit. Quantitative measurement of 31 Human Serum Abundant serum proteins. Suitable for all liquid sample types.
Sample Type Body Fluids, Cell Culture Supernatant, Plasma, Serum, Cell Lysate, Tissue Lysate
Analytical Method Quantitative
Detection Method Fluorometric
Specificity ALCAM (CD166), Angiotensinogen (SERPINA8), ANGPTL3, Cathepsin B (Pro-Cathepsin B), Chemerin, CHI3L1, Cystatin C, Decorin, DKK-3, ErbB3, GASP-1 (WFIKKNRP), ICAM-1 (CD54), IL-1 R3 (IL-1 R Acp), IL-6 R, LAP/TGF beta 1, MIP-1 delta (CCL15), MSP alpha/beta, NAP-2 (PPBP/CXCL7), NOV (CCN3), PARC (CCL18), P-Cadherin, PDGF-AA, PDGF-BB, PGRPs, RANTES (CCL5), SCF R (CD117/c-kit), Siglec-5 (CD170), TIMP-1, TIMP-2, Trappin-2, VCAM-1 (CD106)
Characteristics
  • Running an array is like running dozens of ELISAs simultaneously.
  • Quantibody arrays are stunningly simple to use, read, and analyze.
  • Each panel can quantify up to 40 different biomarkers simultaneously, and individual panels can be multiplexed to quantify as many as 660 different biomarkers at one time.
  • The entire process can be completed in just 4-6 hours.
  • More cost-effective than traditional ELISA
  • High specificity and system reproducibility
  • Suitable for diverse sample types
  • Low sample volume requirement: 50 μL or less
  • Well-suited for high throughput assays

  • More cost-effective than traditional ELISA
  • High specificity and system reproducibility
  • Suitable for diverse sample types
  • Low sample volume requirement: 50 μL or less
  • Get results same day (6-hour processing time)
  • Well-suited for high throughput assays
  • Q Analyzer software provides one-step computation
Components Glass Chip with antibody arrays
Sample Diluent
Lyophilized protein standard mix
Detection antibody cocktail
Streptavidin-Fluorescent dye
Wash buffer
Material not included Distilled or deionized water
Small plastic boxes or containers
Pipettors, pipette tips and other common lab consumables
Orbital shaker or oscillating rocker
Aluminum foil
Gene microarray scanner or similar laser fluorescence scanner
Application Notes Completely cover array area with sample or buffer during incubation. Avoid foaming during incubation steps. Perform all incubation and wash steps under gentle rocking or rotation. Cover the incubation chamber with adhesive film during incubation, particularly when incubation is more than 2 hours or <70?μl 6="" 7="" 10="" 13="" of="" sample="" or="" reagent="" is="" used.="" several="" incubation="" steps="" such="" as="" step="" (blocking),="" (sample="" incubation),="" (detection="" antibody="" (cy3="" equivalent="" dyestreptavidin="" incubation)="" may="" be="" done="" overnight="" at="" 4?°c.="" please="" make="" sure="" to="" cover="" the="" chamber="" tightly="" prevent="" evaporation.="" <="" td="">
Comment

The Quantibody arrays are quantitative multiplex ELISA arrays featuring fluorescent detection. The antibodies are spotted on glass slide solid supports and require a laser scanner for data collection. Cytokine standards are provided with the array for calculation of target protein concentrations.
All Quantibody arrays feature the sandwich immunoassay principle, utilizing an immobilized capture antibody along with a corresponding biotinylated detection antibody.

Sample Volume 100 μL
Plate Glass Slide
Protocol
  1. Each Quantibody array starts with a single glass microscope slide, which acts as a support for the array. Slides are segmented using a rubber gasket. Up to 8 samples may assayed using a single slide.
  2. Antibodies against a variety of different antigens (up to 40 biomarkers per slide) are printed onto the glass slide. Replicates are included, saving you both time and precious sample volume.
  3. The end-user adds either known concentration standards (included) or aqueous sample to each well on the slide. Antibodies on the slide capture antigen off from the sample or standard.
  4. The end-user adds a detection mix containing paired antibodies (compatible with the primaries pre-coated on the slide) conjugated to a fluorescent dye for detection.
  5. Fluorescent signal from each spot is read using a laser slide scanner. The intensity from each spot is compared to the standard curve, and a quantitative expression profile for relevant biomarkers is established.
Restrictions For Research Use only
Handling Advice Do not touch the surface of the slides, as the microarray slides are very sensitive. Hold the slides by the edges only. Handle all buffers and slides with powder free gloves. Handle glass slide/s in clean environment. The Quantibody slides do not have bar codes. To help distinguish one slide from another, transcribe the slide serial number from the slide bag to the back of the slide with an ultra-fine point permanent marker. Please Note:Red permanent marker can significantly interfere with fluorescent signal detection. We recommend marking your slides with a green, blue or black ultra-fine point permanent marker. Please write the number on the very bottom edge of the slide. Do not write on the arrayed well areas.
Storage -20 °C
Storage Comment For best results, store the entire kit frozen at -20°C upon arrival. Stored frozen, the kit will be stable for at least 6 months which is the duration of the product warranty period. Once thawed, store array slide(s), standard mix, detection antibody cocktail, and Cy3-Conjugated Streptavidin at -20°C and all other reagents undiluted at 4°C for no more than 3 months.
Supplier Images
 image for Human Serum Abundant Protein Array Q1 (ABIN4956068) Human Serum Abundant Protein Array Q1
鄂尔多斯市| 南部县| 康乐县| 越西县| 延长县| 荆州市| 寻乌县| 明水县| 宁阳县| 吉隆县| 东兰县| 大兴区| 施甸县| 汤阴县| 陆川县| 湟中县| 黔南| 阳信县| 鸡泽县| 武胜县| 桦南县| 泽州县| 基隆市| 大田县| 中卫市| 达日县| 阿城市| 阜南县| 平安县| 天长市| 安达市| 阳新县| 陆川县| 日照市| 德安县| 康定县| 高雄县| 日喀则市| 亳州市| 吉隆县| 崇明县|